Fire Protection Systems
Fire Protection Systems

Fire Protection Systems

Design, calculation and planning of fire protection systems, according to the standards and guidelines from NFPA and FM Global after a risk analysis and definition of the type of industry to protect. We use Autosprink, our specialized software for hydraulic calculation and dimensioning of the systems. We plan and coordinate supply and logistics in order to reduce the total time on site, which reflects in significant project savings. We provide consulting and maintenance services complying NFPA regulations to cover the requirements insurers have for the industry.

Fire Protection Systems

Design, calculation and planning of fire protection systems, according to the standards and guidelines from NFPA and FM Global after a risk analysis and definition of the type of industry to protect. We use Autosprink, our specialized software for hydraulic calculation and dimensioning of the systems. We plan and coordinate supply and logistics in order to reduce the total time on site, which reflects in significant project savings. We provide consulting and maintenance services complying NFPA regulations to cover the requirements insurers have for the industry.

Supression


  • Hydrant and hose systems.
  • Fire pump systems.
  • Deluge systems.
  • Foam fire suppression systems.
  • Clean agent fire extinguishing systems.

Detection


  • Fire detection and alarm system.
  • Air sampling detection.
  • Fire alarm control panel.
  • Fire doors, panic bars and accessories.

Supression

Avatar
  • Hydrant and hose systems.
  • Fire pump systems.
  • Deluge systems.
  • Foam fire suppression systems.
  • Clean agent fire extinguishing systems.

Detection

Avatar
  • Fire detection and alarm system.
  • Air sampling detection.
  • Fire alarm control panel.
  • Fire doors, panic bars and accessories.

Where Do We Protect The Effects Of Fire?

Where Do We Protect The Effects Of Fire?

Industrial Parks and warehouses

Commercial Establishments

Hotels

Logistic Centers

Airports

Marine Applications

Laboratories

Cultural Buildings

Residential Buildings

Museums / Heritage Protected Buildings

Design and Planning



Design, calculation and planning of fire protection systems, according to the standards and guidelines from NFPA and FM Global after a risk analysis and definition of the type of industry to protect. We use Autosprink, our specialized software for hydraulic calculation and dimensioning of the systems. We plan and coordinate supply and logistics in order to reduce the total time on site, which reflects in significant project savings. We provide consulting and maintenance services complying NFPA regulations to cover the requirements insurers have for the industry.


Design and Planning



Design, calculation and planning of fire protection systems, according to the standards and guidelines from NFPA and FM Global after a risk analysis and definition of the type of industry to protect. We use Autosprink, our specialized software for hydraulic calculation and dimensioning of the systems. We plan and coordinate supply and logistics in order to reduce the total time on site, which reflects in significant project savings. We provide consulting and maintenance services complying NFPA regulations to cover the requirements insurers have for the industry.

1. A project manager will accompany you in each stage of the project.

2. We carry out an exhaustive analysis of associated risks needed to safeguard, considering the daily reality that the establishment has or will have.

3. We provide design approach proposal, selecting the correct interaction of the protection system to achieve a better efficiency.

5. Installation and commissioning of fire protection systems, complying with industrial safety requirements and carrying out necessary tests to guarantee fault-free operations.

6. Proposal for preventive and corrective maintenance of the facilities.

Certification and Regulatory Compliance

NFPA (National Fire Protection Association) is an organization founded un the United States in 1986 that is in charge of creating and updating the standards and minimum requirements for designing fire protection systems, as well as training in the installation and use of the fire protection equipment used by firemen and the safety marshal and brigade in the company. It’s standards, known as National Fire codes, recommends safe practices developed by expert personnel in fire control.

FM global is a North American insurance company that specializes in loss prevention services, mainly to large corporations across the world in the Highly Protected Risk (HPR) property market.

An FM aproved logo is given by the FM Global testing agency branch after carrying out testing procedures to ensure that products destined to be used in commercial and industrial applications compel the highest standards for safety and loss prevention in matters of technical integrity, performance and quality.

Notifier by Honeywell is a manufacturer of fire alarm and detection system devices designed to compel with NFPA standards.

Kidde is a brand of United Technologies Corporation. Is a manufacturer of smoke and carbon monoxide devices and fire alarm and notification devices.

Novec 1230 is a liquid agent manufactured by 3M, designed for fire suppression in areas where water-based suppression systems result impractical due the damage that may occur in electrical and electronic components as in important files and documents by being in contact with water.

Vortex is a hybrid fire suppression system designed for areas where water based suppression systems are not an economically viable option due the high value of the assets to protect. It works by discharging a distilled water and nitrogen mixture in the room where the asset is located, lowering the temperature and creating an atmosphere where the fire cannot exist. It is used for the protection of server rooms, electrical equipment, machine rooms, etc.

Auto Sprink is a specialized software for the design, calculation and sizing of water-based fire protection systems. Is used to design sprinkler systems according to NFPA 13 standards, standpipe and fire hose systems, pump sizing calculation and simulating the system demand in fire combat scenarios.

Product Enquiry